protective coats thermal insulation materials.fire resistance of the building structure.application temperature thermal insulation materials.lambda coefficient of thermal insulation materials.application of thermal insulation materials.The used tools must be washed immediately after use. The areas surrounding the application surface must be covered with duct tape and protection foil. Do not dilute the material with water and do not mix it with other construction materials. sealed surfaces will be protected against rain and frost for at least 4 hours since the application. In the case of strong sunlight, the water insulation will be applied in a shady area. RECOMMENDATIONS: All works will be executed at an air and support temperature of +3oC to +30oC and bad weather conditions are to be avoided (rain, snow, strong winds, direct sunlight). The adhesion time is influenced by weather. Surfaces can be exposed to constant water action after 3 days. 4 hours since applying the last layer of sealant. 90 minutes while horizontal surfaces such as floors become functional and can be cladded with ceramic tiles after approx. On vertical surfaces such as walls, ceramic claddings can be done after approx. In order to ensure a tension-free drying, the quantity on a layer must not be bigger than 1,5 kg/m. The following layer can be applied once the first one cannot be deteriorated by applying a new one. The minimum layer must be respected in each and every point of the soon to be sealed surface. The first layer of Weber.Tec Superflex D2 must be applied on the entire surface of the support which was prepared in a compact layer (approx. In order to obtain a waterproof layer you need to apply at least two layers (3 layers for the surfaces exposed to water under pressure). The obtained paste must be applied with a brush, roller, paintbrush, mechanical or steel trowel. The mixing ratio must be 1:1 in terms of weight. Mix the two components using an electric mixer for two-three minutes (at a maximum torque of 800 rpm) until a homogenous paste is obtained. Pour one liquid component into a bucket, over which you must add the powder component. WORK AND PREPARATION METHOD: The flexible Weber.Tec Superflex D2 water insulation is a bicomponent material: a liquid-pasty component and a powder one. The cracks and cavities larger than 5 mm must be closed and filled. The margins, edges and corners must be rounded and lumps must be leveled out. sealed parts and residues which may diminish the adherence must be removed. SUPPORT PREPARATION: The supporting surface must be clean, undeformable, dry, fixed, free of slippery surfaces (grease, bitumen, tar, dust etc.), must not present frost traces, free of large cracks or lumps. Contains high reactivity polymers, reactive filling materials and additives.Ģ components, in plastic buckets of 5 kg (60 buckets/pallet).Ģ components, in plastic buckets of 20 kg (18 buckets/pallet). The Weber.Tec Superflex D2 is a flexible bicomponent water insulation with fast adhesion, based on cement and quartz sand. Especially recommended as a sealant underneath natural stone and ceramic claddings. It can also be used as an adhesive for extruded polystyrene, rigid foam tiles and miner fiber tiles. As a preliminary sealing and binding layer under a polymeric modified bitumen, the water insulation goes on under brickworks and binding layers on old anionic bitumen surfaces. It can also be used for sealing the underground walls at the interior as well as for sealing water tanks (found indoor, with water column of maximum 15 m). Flexible bicomponent water insulation for both the interior and the exterior, most often used on cellar walls made out of brick or concrete, underground walls, concrete walls, foundations etc.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |